Diagnosis Procedure
- INSPECTION START
Confirm the detected DTC.
Which DTC is detected?
P0102, P010C: GO TO 2.
P0103, P010D: GO TO 3.
- CHECK INTAKE SYSTEM
Check the following for connection.
- Air duct
- Vacuum hoses
- Intake air passage between air duct to intake manifold
Is the inspection result normal?
YES: GO TO 3.
NO: Reconnect the parts.
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in "CIRCUIT INSPECTION ".
Is the inspection result normal?
YES: GO TO 4.
NO: Repair or replace ground connection.
- CHECK MAF SENSOR POWER SUPPLY CIRCUIT
- Disconnect mass air flow (MAF) sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between MAF sensor harness connector and ground.VOLTAGE SPECIFICATIONS
DTC MAF sensor Ground Voltage Bank Connector Terminal P0102, P0103 1 F31 5 Ground Battery voltage P010C, P010D 2 F42 5
Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E106, M6
- Harness connectors M116, F103
- Harness for open or short between mass air flow sensor and ECM
- Harness for open or short between mass air flow sensor and IPDM E/R
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK MAF SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between MAF sensor harness connector and ECM harness connector.CONTINUITY SPECIFICATIONS
DTC MAF sensor ECM Continuity Bank Connector Terminal Connector Terminal P0102, P0103 1 F31 4 F102 68 Existed P010C, P010D 2 F42 4 94 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 7.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK MAF SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between MAF sensor harness connector and ECM harness connector.CONTINUITY SPECIFICATIONS
DTC MAF sensor ECM Continuity Bank Connector Terminal Connector Terminal P0102, P0103 1 F31 3 F102 77 Existed P010C, P010D 2 F42 3 79 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 8.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- Check the continuity between MAF sensor harness connector and ECM harness connector.
- CHECK MASS AIR FLOW SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 9.
NO: Replace malfunctioning mass air flow sensor.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END