Component Function Check
- PERFORM COMPONENT FUNCTION CHECK
With GST
CAUTION:- Do not use compressed air, doing so may damage the EVAP system.
- Do not start engine.
- Do not exceeded 4.12 kPa (0.042 kg/cm2 , 0.6 psi).
- Attach the EVAP service port adapter securely to the EVAP service port.
- Set the pressure pump and a hose.
- Also set a vacuum gauge via 3-way connector and a hose.
- Turn ignition switch ON.
- Connect GST and select Service $08.
- Using Service $08 control the EVAP canister vent control valve (close).
- Apply pressure and make sure the following conditions are satisfied.
Pressure to be applied: 2.7 kPa (0.028 kg/cm 2 , 0.39 psi) Time to be waited after the pressure drawn in to the EVAP system and the pressure to be dropped: 60 seconds and the pressure should not be dropped more than 0.4 kPa (0.004 kg/cm 2 , 0.06 psi).
Is the inspection result normal?
YES: GO TO 2.
NO: Go to "DIAGNOSIS PROCEDURE ".
- RELEASE PRESSURE
- Disconnect GST.
- Start engine and warm it up to normal operating temperature.
- Turn ignition switch OFF and wait at least 10 seconds.
- Restart engine and let it idle for 90 seconds.
- Keep engine speed at 2, 000 rpm for 30 seconds.
- Turn ignition switch OFF.NOTE: For more information, refer to GST Instruction Manual.
INSPECTION END