Battery Current Sensor
- Reconnect harness connectors disconnected.
- Disconnect battery negative cable (1).
- Install jumper 1cable (A) between battery negative terminal and body ground.
- Turn ignition switch ON.
- Check voltage between ECM terminal 71 (battery current sensor signal) and ground.
Voltage: Approximately 2.5V
- If NG, replace battery negative cable assembly.