Fail-Safe Input/Cancel Conditions
FAIL-SAFE CONDITIONS CHART
| Input conditions | Cancel conditions |
|---|---|
| When vehicle runs at an engine speed of 1, 500 rpm or higher and no vehicle speed signal is received for 10 seconds. |
|
| The continuous vehicle speed signal 30 km/h (19 MPH) or more suddenly drops to less than 2 km/h (1.2 MPH) within 1.4 seconds. |
CAUTION:
Fail-safe function is activated when the engine runs at 1, 500 rpm or higher for 10 seconds with the vehicle stopped. This is normal and the fail-safe function is automatically deactivated when a vehicle speed signal of 2 km/h (1.2 MPH) or higher is input or the ignition switch is turned OFF.