LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Infiniti >> 2010 >> M35 Base >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System - System And Component Testing >> Cooling Fan >> Diagnosis Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Diagnosis Procedure

  1. CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT-I
    1. Turn ignition switch OFF.
    2. Disconnect cooling fan control module harness connector.
    3. Turn ignition switch ON.
    4. Check the voltage between cooling fan control module harness connector and ground.
      CONNECTOR TERMINAL VOLTAGE CHART

      Cooling fan control module Ground Voltage
      Connector Terminal
      E42 3 Ground Battery voltage
      Fig 1: Checking Voltage Between Cooling Fan Control Module Terminal 3 And Ground
      G05209994Courtesy of NISSAN MOTOR CO., U.S.A.

      Is the inspection result normal? 

      YES: GO TO 2.

      NO: GO TO  7.

  2. CHECK COOLING FAN CONTROL MODULE GROUND CIRCUIT
    1. Turn ignition switch OFF.
    2. Check the continuity between cooling fan control module harness connector and ground.
      CONNECTOR TERMINAL CONTINUITY CHART

      Cooling fan control module Ground Continuity
      Connector Terminal
      E42 1 Ground Existed
    3. Also check harness for short to power.

      Is the inspection result normal? 

      YES: GO TO 3.

      NO: Repair open circuit or short to power in harness or connectors.

  3. CHECK IPDM E/R GROUND CIRCUIT
    1. Disconnect IPDM E/R harness connectors.
    2. Check the continuity between IPDM E/R harness connector and ground.
      CONNECTOR TERMINAL CONTINUITY CHART

      IPDM E/R Ground Continuity
      Connector Terminal
      E8 38 Ground Existed
      E9 51
    3. Also check harness for short to power.

      Is the inspection result normal? 

      YES: GO TO 4.

      NO: Repair open circuit or short to power in harness or connectors.

  4. CHECK COOLING FAN CONTROL SIGNAL CIRCUIT
    1. Disconnect IPDM E/R harness connector.
    2. Check the continuity between IPDM E/R harness connector and cooling fan control module harness connector.
      CONNECTOR TERMINAL CONTINUITY CHART

      IPDM E/R Cooling fan control module Continuity
      Connector Terminal Connector Terminal
      E9 59 E42 2 Existed
    3. Also check harness for short to ground and short to power.

      Is the inspection result normal? 

      YES: GO TO 5.

      NO: Repair open circuit, short to ground or short to power in harness or connectors.

  5. CHECK COOLING FAN CONTROL MODULE OUTPUT SIGNAL CIRCUIT
    1. Reconnect all harness connectors disconnected.
    2. Disconnect cooling fan control module harness connectors.
    3. Turn ignition switch ON.
    4. Check the voltage between cooling fan control module terminals and ground.
      CONNECTOR TERMINAL VOLTAGE CHART

      Cooling fan control module Ground Voltage
      Connector Terminal
      E301 4 Ground Battery voltage
      E303 6
      Fig 2: Checking Voltage Between Cooling Fan Control Module Terminals 4, 6 And Ground
      G05209995Courtesy of NISSAN MOTOR CO., U.S.A.

      Is the inspection result normal? 

      YES: GO TO 6.

      NO: Replace cooling fan control module 1.

  6. CHECK COOLING FAN MOTORS -1 AND -2

    Refer to "COMPONENT INSPECTION (COOLING FAN MOTOR) ".

    Is the inspection result normal? 

    YES: GO TO  11.

    NO: Replace malfunctioning cooling fan motor.

  7. CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT-II
    1. Turn ignition switch OFF.
    2. Disconnect cooling fan relay.
    3. Turn ignition switch ON.
    4. Check the voltage between cooling fan relay harness connector and ground.
      CONNECTOR TERMINAL VOLTAGE CHART

      Cooling fan relay Ground Voltage
      Connector Terminal
      E32 2 Ground Battery voltage
      3
      Fig 3: Checking Voltage Between Cooling Fan Relay Terminals And Ground
      G06306794Courtesy of NISSAN MOTOR CO., U.S.A.

      Is the inspection result normal? 

      YES: GO TO  9.

      NO: GO TO 8.

  8. DETECT MALFUNCTIONING PART

    Check the following.

    • 10 A fuse (No. 12)
    • Fuse block (J/B) connector E102
    • 50 A fusible link (letter I)
    • Harness for open or short between cooling fan relay and fuse
    • Harness for open or short between cooling fan relay and battery

      Repair open circuit, short to ground or short to power in harness or connectors.

  9. CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT-III
    1. Turn ignition switch OFF.
    2. Disconnect IPDM E/R harness connector.
    3. Check the continuity between cooling fan relay harness connector and IPDM E/R harness connector.
      CONNECTOR TERMINAL CONTINUITY CHART

      Cooling fan relay IPDM E/R Continuity
      Connector Terminal Connector Terminal
      E32 1 E9 56 Existed
    4. Check the continuity between cooling fan relay harness connector and cooling fan control module harness connector.
      CONNECTOR TERMINAL CONTINUITY CHART

      Cooling fan relay Cooling fan control module Continuity
      Connector Terminal Connector Terminal
      E32 5 E42 3 Existed
    5. Also check harness for short to ground and short to power.

      Is the inspection result normal? 

      YES: GO TO 10.

      NO: Repair open circuit, short to ground or short to power in harness or connectors.

  10. CHECK COOLING FAN RELAY

    Refer to "COMPONENT INSPECTION (COOLING FAN RELAY) ".

    Is the inspection result normal? 

    YES: GO TO 11.

    NO: Replace cooling fan relay.

  11. CHECK INTERMITTENT INCIDENT

    Perform "DESCRIPTION ".

    Is the inspection result normal? 

    YES: Replace IPDM E/R.

    NO: Repair or replace harness connectors.