Diagnosis Procedure
- CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT-I
- Turn ignition switch OFF.
- Disconnect cooling fan control module harness connector.
- Turn ignition switch ON.
- Check the voltage between cooling fan control module harness connector and ground.TERMINALS VOLTAGE REFERENCE CHART
Cooling fan control module Ground Voltage Connector Terminal E37 3 Ground Battery voltage Is the inspection result normal?
YES: GO TO 2.
NO: GO TO 7.
- CHECK COOLING FAN CONTROL MODULE GROUND CIRCUIT
- Turn ignition switch OFF.
- Check the continuity between cooling fan control module harness connector and ground.TERMINALS CONTINUITY REFERENCE CHART
Cooling fan control module Ground Continuity Connector Terminal E37 1 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 3.
NO: Repair open circuit or short to power in harness or connectors.
- CHECK IPDM E/R GROUND CIRCUIT
- Disconnect IPDM E/R harness connectors.
- Check the continuity between IPDM E/R harness connector and ground.TERMINALS CONTINUITY REFERENCE CHART
IPDM E/R Ground Continuity Connector Terminal E5 12 Ground Existed E6 41 - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 4.
NO: Repair open circuit or short to power in harness or connectors.
- CHECK COOLING FAN CONTROL SIGNAL CIRCUIT
- Disconnect IPDM E/R harness connector.
- Check the continuity between IPDM E/R harness connector and cooling fan control module harness connector.TERMINALS CONTINUITY REFERENCE CHART
IPDM E/R Cooling fan control module Continuity Connector Terminal Connector Terminal E9 97 E37 2 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 5.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK COOLING FAN CONTROL MODULE OUTPUT SIGNAL CIRCUIT
- Reconnect all harness connectors disconnected.
- Disconnect cooling fan control module harness connectors.
- Turn ignition switch ON.
- Check the voltage between cooling fan control module harness connectors and ground.TERMINALS VOLTAGE REFERENCE CHART
Cooling fan control module Ground Voltage Connector Terminal E301 4 Ground Battery voltage E302 6 Is the inspection result normal?
YES: GO TO 6.
NO: Replace cooling fan control module. Refer to "EXPLODED VIEW ".
- CHECK COOLING FAN MOTORS -1 AND -2
Refer to "COMPONENT INSPECTION (COOLING FAN MOTOR) ".
Is the inspection result normal?
YES: GO TO 11.
NO: Replace cooling fan motor. Refer to "EXPLODED VIEW ".
- CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect cooling fan relay harness connector.
- Turn ignition switch ON.
- Check the voltage between cooling fan relay harness connector and ground.TERMINALS VOLTAGE REFERENCE CHART
Cooling fan relay Ground Voltage Connector Terminal E17 2 Ground Battery voltage 3 Is the inspection result normal?
YES: GO TO 9.
NO: GO TO 8.
- DETECT MALFUNCTIONING PART
Check the following.
- 10 A fuse (No. 42)
- IPDM E/R harness connector E7
- 50 A fusible link (letter F)
- Harness for open or short between cooling fan relay and fuse
- Harness for open or short between cooling fan relay and battery
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT-III
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between cooling fan relay harness connector and IPDM E/R harness connector.TERMINALS CONTINUITY REFERENCE CHART
Cooling fan relay IPDM E/R Continuity Connector Terminal Connector Terminal E17 1 E6 42 Existed - Check the continuity between cooling fan relay harness connector and cooling fan control module harness connector.TERMINALS CONTINUITY REFERENCE CHART
Cooling fan relay Cooling fan control module Continuity Connector Terminal Connector Terminal E17 5 E37 3 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 10.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK COOLING FAN RELAY
Refer to "COMPONENT INSPECTION (COOLING FAN RELAY) ".
Is the inspection result normal?
YES: GO TO 11.
NO: Replace cooling fan relay. Refer to "COMPONENT PARTS LOCATION "
- CHECK INTERMITTENT INCIDENT
Perform "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".