Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connection.
- VVEL ACTUATOR MOTOR OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Disconnect VVEL control module harness connector.
- Disconnect VVEL actuator motor harness connector.
- Check the continuity between VVEL control module harness connector and VVEL actuator motor harness connector.CONTINUITY REFERENCE
DTC No. VVEL control module VVEL actuator motor Continuity Bank Connector Terminal Connector Terminal P100A 1 E15 12 F48 1 Existed 2 Not existed 25 1 Not existed 2 Existed P100B 2 2 F49 1 Existed 2 Not existed 15 1 Not existed 2 Existed - Also check harness for short to ground and power.
Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 3.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F40, E20
- Harness for open or short between VVEL actuator motor and VVEL control module
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK VVEL ACTUATOR MOTOR
Refer to "COMPONENT INSPECTION (VVEL ACTUATOR MOTOR) ".
Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- REPLACE VVEL ACTUATOR SUB ASSEMBLY
- Replace VVEL actuator sub assembly.
- Go to
"SPECIAL REPAIR REQUIREMENT ".
INSPECTION END
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: GO TO 7.
NO: Repair or replace.
- REPLACE VVEL CONTROL MODULE
- Replace VVEL control module.
- Go to
"WORK PROCEDURE
".
GO TO 8.
- PERFORM DTC CONFIRMATION PROCEDURE
- Turn ignition switch ON.
- Erase DTC.
- Perform DTC Confirmation Procedure.
See "DTC LOGIC ".
Is the DTC P100A or P100B displayed again?
YES: GO TO 9.
NO: INSPECTION END
- CHECK VVEL ACTUATOR SUB ASSEMBLY
Refer to "COMPONENT INSPECTION (VVEL ACTUATOR SUB ASSEMBLY) ".
Is the inspection result normal?
YES: GO TO 11.
NO: GO TO 10.
- REPLACE VVEL ACTUATOR SUB ASSEMBLY
- Replace VVEL actuator sub assembly.
- Go to
"SPECIAL REPAIR REQUIREMENT ".
INSPECTION END
- CHECK VVEL LADDER ASSEMBLY
Refer to "INSPECTION ".
Is the inspection result normal?
YES: GO TO 13.
NO: GO TO 12.
- REPLACE CYLINDER HEAD, VVEL LADDER ASSEMBLY AND VVEL ACTUATOR SUB ASSEMBLY
- Replace cylinder head, VVEL ladder assembly and VVEL actuator sub assembly.
- Go to
"SPECIAL REPAIR REQUIREMENT ".
INSPECTION END
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END