Diagnosis Procedure
- CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Disconnect refrigerant pressure sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between refrigerant pressure sensor harness connector and ground.VOLTAGE SPECIFICATION
Refrigerant pressure sensor Ground Voltage (V) Connector Terminal E77 1 Ground Approx. 5 Is the inspection result normal?
YES: GO TO 3.
NO: GO TO 2.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open or short between ECM and refrigerant pressure sensor
- Loose or poor connection for each connector and harness
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.CONTINUITY SPECIFICATION
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E77 3 E80 150 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 5.
NO: GO TO 4.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open or short between ECM and refrigerant pressure sensor
- Loose or poor connection for each connector and harness
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.CONTINUITY SPECIFICATION
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E77 2 E80 144 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 7.
NO: GO TO 6.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open or short between ECM and refrigerant pressure sensor
- Loose or poor connection for each connector and harness
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: Replace refrigerant pressure sensor. Refer to "REFRIGERANT PRESSURE SENSOR : REMOVAL AND INSTALLATION ".
NO: Repair or replace malfunctioning part.