Component Description
| Component part | Description |
|---|---|
| TCM | TCM supplies power to the starter relay and starter control relay inside IPDM E/R when the selector lever is shifted to the P or N position. |
| BCM | BCM controls the starter relay inside IPDM E/R. |
| IPDM E/R | CPU inside IPDM E/R controls the starter control relay. |
| Starter motor | The starter motor plunger closes and the motor is supplied with battery power, which in turn cranks the engine, when the "S" terminal is supplied with electric power. |