Diagnosis Procedure
- CHECK COOLING FAN CONTROL MODULE 1 POWER SUPPLY CIRCUIT-I
- Turn ignition switch OFF.
- Disconnect cooling fan control module harness connector E37.
- Turn ignition switch ON.
- Check the voltage between cooling fan control module 1 harness connector and ground.
Cooling fan control module 1 Ground Voltage Connector Terminal E37 3 Ground Battery voltage Is the inspection result normal?
YES: GO TO 2.
NO: GO TO 7.
- CHECK COOLING FAN CONTROL MODULE GROUND CIRCUIT
- Turn ignition switch OFF.
- Check the continuity between cooling fan control module 1 harness connector and ground.
Cooling fan control module 1 Ground Continuity Connector Terminal E37 1 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 3.
NO: Repair open circuit or short to power in harness or connectors.
- CHECK IPDM E/R GROUND CIRCUIT
- Disconnect IPDM E/R harness connectors E5, E6.
- Check the continuity between IPDM E/R harness connector and ground.
IPDM E/R Ground Continuity Connector Terminal E5 12 Ground Existed E6 41 - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 4.
NO: Repair open circuit or short to power in harness or connectors.
- CHECK COOLING FAN CONTROL SIGNAL CIRCUIT
- Disconnect IPDM E/R harness connector E9.
- Check the continuity between IPDM E/R harness connector and cooling fan control module 1 harness connector.
IPDM E/R Cooling fan control module 1 Continuity Connector Terminal Connector Terminal E9 97 E37 2 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 5.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK COOLING FAN CONTROL MODULE 1 OUTPUT SIGNAL CIRCUIT
- Reconnect all harness connectors disconnected.
- Disconnect cooling fan control module 1 harness connectors E301, E302.
- Turn ignition switch ON.
- Check the voltage between cooling fan control module 1 terminals and ground.
Cooling fan control module 1 Ground Voltage Terminal 4 Ground Battery voltage 6 Is the inspection result normal?
YES: GO TO 6.
NO: Replace cooling fan control module 1. Refer to "COMPONENT PARTS LOCATION ".
- CHECK COOLING FAN MOTORS -1 AND -2
Refer to "COMPONENT INSPECTION (COOLING FAN MOTOR) ".
Is the inspection result normal?
YES: GO TO 11.
NO: Replace malfunctioning cooling fan motor. Refer to "REMOVAL AND INSTALLATION ".
- CHECK COOLING FAN CONTROL MODULE 1 POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect cooling fan relay 1.
- Turn ignition switch ON.
- Check the voltage between cooling fan relay 1 harness connector and ground.
Cooling fan relay 1 Ground Voltage Connector Terminal E15 1 Ground Battery voltage 3 Is the inspection result normal?
YES: GO TO 9.
NO: GO TO 8.
- DETECT MALFUNCTIONING PART
Check the Following:
- 10 A fuse (No. 42)
- IPDM E/R harness connector E7
- 50 A fusible link (letter O)
- Harness for open or short between cooling fan relay 1 and fuse
- Harness for open or short between cooling fan relay 1 and battery
: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK COOLING FAN CONTROL MODULE 1 POWER SUPPLY CIRCUIT-III
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector E6.
- Check the continuity between cooling fan relay 1 harness connector and IPDM E/R harness connector.
Cooling fan relay 1 IPDM E/R Continuity Connector Terminal Connector Terminal E15 2 E6 42 Existed - Check the continuity between cooling fan relay 1 harness connector and cooling fan control module 1 harness connector.
Cooling fan relay 1 Cooling fan control module 1 Continuity Connector Terminal Connector Terminal E15 5 E37 3 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 10.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK COOLING FAN RELAY 1
Refer to "COMPONENT INSPECTION (COOLING FAN RELAY) ".
Is the inspection result normal?
YES: GO TO 11.
NO: Replace cooling fan relay 1.
- CHECK INTERMITTENT INCIDENT
Perform "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness connectors.