Component Function Check
- PERFORM COMPONENT FUNCTION CHECK
ⓧ Without CONSULT
- Perform "INSPECTION MODE 5". Refer to "DESCRIPTION ".
- Start engine and warm it up to the normal operating temperature.
- Turn ignition switch OFF and wait at least 10 seconds.
- Start engine and keep the engine speed at 3, 000 RPM for at least 1 minute under no load.
- Perform "INSPECTION MODE 5". Refer to "DESCRIPTION ".
- Let engine idle for 1 minute.
- Open engine hood.
- Check the voltage between ECM harness connector terminals under the following condition.
DTC ECM Condition Voltage Connector + - Terminal Terminal P0420 F102 76 [HO2S2 (bank 1)] 84 Keeping engine speed at 3, 000 RPM constant under no load The voltage fluctuation cycle takes more than 5 seconds. - 1 cycle: 0.6 - 1.0→ 0 - 0.3 → 0.6 - 1.0
P0430 80 [HO2S2 (bank 2)] Is the inspection result normal?
YES: INSPECTION END
NO: Go to "DIAGNOSIS PROCEDURE ".