Diagnosis Procedure
- CHECK INTAKE SYSTEM
Check the following for connection.
- Air duct
- Vacuum hoses
- Intake air passage between air duct and intake manifold
Is the inspection result normal?
YES: GO TO 2.
NO: Reconnect the parts.
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace ground connection.
- CHECK MASS AIR FLOW (MAF) SENSOR POWER SUPPLY
- Disconnect MAF sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between MAF sensor harness connector and ground.
DTC MAF sensor Ground Voltage (V) Bank Connector Terminal P0101 1 F31 1 Ground Approx. 5 P010B 2 F42 1 Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 4.
- CHECK MASS AIR FLOW (MAF) SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between MAF sensor harness connector and ECM harness connector.
DTC MAF sensor ECM Continuity Bank Connector Terminal Connector Terminal P0101 1 F31 1 F102 74 Existed P010B 2 F42 1 - Also check harness for short to ground and short to power. Is the inspection result normal?
YES: GO TO 5.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK SENSOR POWER SUPPLY 2 CIRCUIT
Check sensor power supply 2 circuit. Refer to "DIAGNOSIS PROCEDURE ".
Is the inspection result normal?
YES: GO TO 10.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK MAF SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between MAF sensor harness connector and ECM harness connector.
DTC MAF sensor ECM Continuity Bank Connector Terminal Connector Terminal P0101 1 F31 2 F102 68 Existed P010B 2 F42 2 94 - Also check harness for short to ground and short to power. Is the inspection result normal?
YES: GO TO 7.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK MAF SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between MAF sensor harness connector and ECM harness connector.
DTC MAF sensor ECM Continuity Bank Connector Terminal Connector Terminal P0101 1 F31 3 F102 77 Existed P010B 2 F42 3 79 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 8.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- Check the continuity between MAF sensor harness connector and ECM harness connector.
- CHECK INTAKE AIR TEMPERATURE SENSOR
Check intake air temperature sensor (bank 1). Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 9.
NO: Replace MAF sensor (bank 1) (with intake air temperature sensor). Refer to "EXPLODED VIEW ".
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Check EVAP control system pressure sensor. Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 10.
NO: Replace EVAP control system pressure sensor. Refer to "EXPLODED VIEW ".
- CHECK MAF SENSOR
Check MAF sensor. Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 11.
NO: Replace malfunctioning mass air flow sensor. Refer to "EXPLODED VIEW ".
- CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
: INSPECTION END