Component Inspection (Cooling Fan Motor)
- CHECK COOLING FAN MOTOR
- Turn ignition switch OFF.
- Disconnect cooling fan control module harness connectors.
- Supply cooling fan control module terminals with battery voltage and check operation.
Cooling fan control module Operation Motor Connector Terminal (+) (-) 1 E301 4 5 Cooling fan operates. 2 E302 6 7 Is the inspection result normal?
YES: INSPECTION END
NO: Replace cooling fan motor. Refer to "EXPLODED VIEW ".