Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connection.
- CHECK VVEL CONTROL MODULE GROUND CIRCUIT FOR OPEN AND SHORT
- Disconnect VVEL control module harness connector.
- Check the continuity between VVEL control module harness connector and ground.
VVEL control module Ground Continuity Connector Terminal E15 14 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 3.
NO: Repair open circuit, short to power in harness connectors.
- CHECK VVEL CONTROL MODULE POWER SUPPLY CIRCUIT-I
- Reconnect VVEL control module harness connector.
- Turn ignition switch ON.
- Check the voltage between VVEL control module harness connector and ground.
VVEL control module Voltage Connector + - Terminal Terminal E15 8 14 After turning ignition switch OFF, battery voltage will exist for a few seconds, then drop to approximately 0 V. Is the inspection result normal?
YES: GO TO 5.
NO: GO TO 4.
- CHECK VVEL CONTROL MODULE POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF and wait at least 10 seconds.
- Disconnect VVEL control module harness connector.
- Disconnect IPDM E/R harness connector.
- Check the continuity between VVEL control module harness connector and IPDM E/R harness connector.
VVEL control module IPDM E/R Continuity Connector Terminal Connector Terminal E15 8 E7 49 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: "DIAGNOSIS PROCEDURE "
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: Replace IPDM E/R. Refer to "EXPLODED VIEW ".