Physical Values
NOTE:
- VVEL control module is located under the battery. Temporarily remove the battery to check voltage of the terminals.
- Specification data are reference values and are measured between each terminals.
- Pulse signal is measured by CONSULT.
| Terminal No. | Description | Condition | Value (Approx.) | ||||
|---|---|---|---|---|---|---|---|
| + | - | Signal name | Input/Output | ||||
| 1 (W) | 14 (B/R) | VVEL actuator motor power supply (bank 2) | Input | [Ignition switch: ON] | BATTERY VOLTAGE (11 - 14V) |
||
| 2 (L/B) | 14 (B/R) | VVEL actuator motor (High lift) (bank 2) | Output | [Engine is running]
|
0 - 14 V(1) | ||
[Engine is running]
|
0 - 14 V(1) | ||||||
| 3 (Y) | 6 (B) | VVEL control shaft position sensor 1 (bank 1) | Input | [Engine is running]
|
0.25 - 1.40 V | ||
[Engine is running]
|
0.25 - 4.75 V | ||||||
| 4 (W) | - | Sensor ground [VVEL control shaft position sensor 1 (bank 2)] | - | - | - | ||
| 5 (L) | 4 (W) | VVEL control shaft position sensor 1 (bank 2) | Input | [Engine is running]
|
0.25 - 1.40 V | ||
[Engine is running]
|
0.25 - 4.75 V | ||||||
| 6 (B) | - | Sensor ground [VVEL control shaft position sensor 1 (bank 1)] | - | - | - | ||
| 7 (W) | 6 (B) | Sensor power supply [VVEL control shaft position sensor 1 (bank 1)] | - | [Ignition switch: ON] | 5 V | ||
| 8 (R) | 14 (B/R) | Power supply for VVEL control module | - | [Ignition switch: ON] | BATTERY VOLTAGE (11 - 14 V) |
||
| 9 (B) | 4 (W) | Sensor power supply [VVEL position sensor 1 (bank 2)] | - | [Ignition switch: ON] | 5 V | ||
| 11 (GR) | - | ENG communication line | Input/Output | - | - | ||
| 12 (L/B) | 14 (B/R) | VVEL actuator motor (High lift) (bank 1) | Output | [Engine is running]
|
0 - 14 V(1) | ||
[Engine is running]
|
0 - 14 V(1) | ||||||
| 13 (W) | 14 (B/R) | VVEL actuator motor power supply (bank 1) | Input | [Ignition switch: ON] | BATTERY VOLTAGE (11 - 14 V) |
||
| 14 (B/R) | - | VVEL control module ground | - | - | - | ||
| 15 (L/W) | 14 (B/R) | VVEL actuator motor (Low lift) (bank 2) | Output | [Engine is running]
|
0 - 14 V(1) | ||
[Engine is running]
|
0 - 14 V(1) | ||||||
| 16 (G) | 19 (L) | VVEL control shaft position sensor 2 (bank 1) | Input | [Engine is running]
|
3.50 - 4.75 V | ||
[Engine is running]
|
0.25 - 4.75 V | ||||||
| 17 (Y) | - | Sensor ground [VVEL control shaft position sensor 2 (bank 2)] | - | - | - | ||
| 18 (R) | 17 (Y) | VVEL control shaft position sensor 2 (bank 2) | Input | [Engine is running]
|
3.50 - 4.75 V | ||
[Engine is running]
|
0.25 - 4.75 V | ||||||
| 19 (L) | - | Sensor ground [VVEL control shaft position sensor 2 (bank 1)] | - | - | - | ||
| 20 (R) | 19 (L) | Sensor power supply [VVEL control shaft position sensor 2 (bank 1)] | - | [Ignition switch: ON] | 5 V | ||
| 21 (V) | 14 (B/R) | VVEL actuator motor relay abort signal [ECM] | Input | [Engine is running]
|
0 V | ||
| 22 (G) | 17 (Y) | Sensor power supply [VVEL control shaft position sensor 2 (bank 2)] | - | [Ignition switch: ON] | 5 V | ||
| 23 (P) | 14 (B/R) | VVEL control motor relay | Output | [Ignition switch: OFF] | BATTERY VOLTAGE (11 - 14 V) |
||
| [Ignition switch: ON] | 0 - 1.0 V | ||||||
| 24 (L) | - | ENG communication line | Input/Output | - | - | ||
| 25 (L/W) | 14 (B/R) | VVEL control motor (Low lift) (bank 1) | Output | [Engine is running]
|
0 - 14 V(1) | ||
[Engine is running]
|
0 - 14 V(1) | ||||||
|
|||||||