Component Function Check
- PRECONDITIONING WARNING: When performing the following procedure, always observe the handling of the fuel. Refer to "GENERAL PRECAUTIONS ".
TESTING CONDITION:
Before starting component function check, preparation of draining fuel and refilling fuel is required.
: GO TO 2.
- PERFORM COMPONENT FUNCTION CHECK NOTE: Start from step 8, if it is possible to confirm that the fuel cannot be drained by 30 l (7-7/8 US gal, 6-5/8 Imp gal) in advance.
- Prepare a fuel container and a spare hose.
- Release fuel pressure from fuel line. Refer to "WORK PROCEDURE ".
- Remove the fuel feed hose on the fuel level sensor unit. Refer to "REMOVAL AND INSTALLATION ".
- Connect a spare fuel hose where the fuel feed hose was removed.
- Turn ignition switch ON.
- Drain fuel by 30 l (7-7/8 US gal, 6-5/8 Imp gal) from the fuel tank using proper equipment.
- Confirm that the fuel gauge indication varies.
- Fill fuel into the fuel tank for 30 l (7-7/8 US gal, 6-5/8 Imp gal).
- Confirm that the fuel gauge indication varies.
Is the inspection result normal?
YES: INSPECTION END
NO: Proceed to "DIAGNOSIS PROCEDURE ".