Initialization Procedure
- Disconnect battery negative terminal or power window control unit connector. Reconnect it after a minute or more.
- Turn ignition switch ON.
- Operate power window switch to fully open door glass. (This operation is unnecessary if door glass is already fully open.)
- Pull and hold power window switch UP (AUTO-UP operation). Even after door glass stops at the fully closed position, pull the switch for 2 seconds or more.
- Initialization procedure is complete.
- Inspect anti-pinch function.