Physical Values
NOTE:
- Specification data are reference values and are measured between each terminal and ground.
- Pulse signal is measured by CONSULT.
| Terminal No. | Description | Condition | Value (Approx.) |
||
|---|---|---|---|---|---|
| + | - - | Signal name | Input/Output | ||
| 1 (W) |
14 (B) |
VVEL actuator motor power supply (bank 2) | Input | [Ignition switch: ON] | BATTERY VOLTAGE (11 - 14 V) |
| 2 (BR) |
14 (B) |
VVEL actuator motor (High lift) (bank 2) | Output | [Engine is running]
|
0 - 14 V |
[Engine is running]
|
0 - 14 V |
||||
| 3 (G) |
4 (B) |
VVEL control shaft position sensor 1 (bank 1) | Input | [Engine is running]
|
Approx.0.25 - 1.40 V |
[Engine is running]
|
Approx.0.25 - 4.75 V | ||||
| 4 (B) |
- | Sensor ground [VVEL control shaft position sensor 1 (bank 1)] |
- | - | - |
| 5 (R) |
6 (B) |
VVEL control shaft position sensor 1 (bank 2) | Input | [Engine is running]
|
Approx.0.25 - 1.40 V |
[Engine is running]
|
Approx.0.25 - 4.75 V | ||||
| 6 (B) |
- | Sensor ground [VVEL control shaft position sensor 1 (bank 2)] |
- | - | - |
| 7 (SB) |
6 (B) |
Sensor power supply [VVEL control shaft position sensor 1 (bank 2)] |
- | [Ignition switch: ON] | 5 V |
| 8 (BG) |
14 (B) |
Power supply for VVEL control module | - | [Ignition switch: ON] | BATTERY VOLTAGE (11 - 14 V) |
| 9 (LG) |
4 (B) |
Sensor power supply [VVEL control shaft position sensor 1 (bank 1)] |
- | [Ignition switch: ON] | 5 V |
| 11 (G) |
- | CAN communication line [ECM] |
Input/Output | - | - |
| 12 (G) |
14 (B) |
VVEL actuator motor (High lift) (bank 1) | Output | [Engine is running]
|
0 - 14 V |
[Engine is running]
|
0 - 14 V |
||||
| 13 (W) |
14 (B) |
VVEL actuator motor power supply (bank 1) | Input | [Ignition switch: ON] | BATTERY VOLTAGE (11 - 14 V) |
| 14 (B) |
- | - | - | [Engine is running]
|
- |
| 15 (G) |
14 (B) |
VVEL actuator motor (Low lift) (bank 2) | Output | [Engine is running]
|
0 - 14 V |
[Engine is running]
|
0 - 14 V |
||||
| 16 (R) |
17 (L) |
VVEL control shaft position sensor 2 (bank 1) | Input | [Engine is running]
|
3.50 - 4.75 V |
[Engine is running]
|
0.25 - 4.75 V | ||||
| 17 (L) |
- | Sensor ground [VVEL control shaft position sensor 2 (bank 1)] |
- | - | - |
| 18 (G) |
19 (W) |
VVEL control shaft position sensor 2 (bank 2) | Input | [Engine is running]
|
3.50 - 4.75 V |
[Engine is running]
|
0.25 - 4.75 V | ||||
| 19 (W) |
- | Sensor ground [VVEL control shaft position sensor 2 (bank 2)] |
- | - | - |
| 20 (BR) |
19 (W) |
Sensor power supply [VVEL control shaft position sensor 2 (bank 2)] |
- | [Ignition switch: ON] | 5 V |
| 21 (V) |
14 (B) |
VVEL actuator motor relay abort signal | Input | [Engine is running]
|
0 V |
| 22 (P) |
17 (L) |
Sensor power supply [VVEL position sensor 2 (bank 1)] |
- | [Ignition switch: ON] | 5 V |
| 23 (Y) |
14 (B) |
VVEL control motor relay | Output | [Ignition switch: OFF] | BATTERY VOLTAGE (11 - 14 V) |
| [Ignition switch: ON] | 0 - 1.0 V | ||||
| 24 (R) |
- | CAN communication line [ECM] | Input/Output | - | - |
| 25 (BR) |
14 (B) |
VVEL control motor (Low lift) (bank 1) | Output | [Engine is running]
|
0 - 14 V |
[Engine is running]
|
0 - 14 V |
||||
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)