Diagnostic Test
- START
Will CONSULT be used?
Will CONSULT be used?
YES
GO TO STEP 2 .
NO
GO TO STEP 3 .
- PERFORM VVEL CONTROL SHAFT POSITION SENSOR ADJUSTMENT
WITH CONSULT
- Turn ignition switch ON.
- Select "VVEL POS SEN ADJ PREP" in "WORK SUPPORT" mode with CONSULT.
- Touch "Start" and wait a few seconds.
- Check that "CMPLT" is displayed on CONSULT screen.
- Select "VVEL POSITION SEN-B1" or "VVEL POSITION SEN-B2" in "DATA MONITOR" mode with CONSULT.
- Loosen the VVEL control shaft position sensor mounting bolts (1).
- Turn the VVEL control shaft position sensor (2) clockwise and counterclockwise while monitoring the output voltage of "VVEL POSITION SEN-B1" or "VVEL POSITION SEN-B2" and adjust the output voltage to be within the standard value.
Voltage: 500 +- 48 mV - Tighten the VVEL control shaft position sensor mounting bolts.
:
7.0 N•m (0.71 kg-m, 62 in-lb) - Reconfirm that the output voltage of "VVEL POSITION SEN-B1" or "VVEL POSITION SEN-B2" is within the standard value.
Voltage: 500 +- 48 mV NOTE:If it varies from the standard value after the mounting bolts are tightened, perform steps 6 to 8 again.
- Turn ignition switch OFF and wait at least 10 seconds.
- Start engine and warm it up to normal operating temperature.
- Turn ignition switch OFF and wait at least 10 seconds.
- Perform idle air volume learning. Refer to DESCRIPTION .
INSPECTION END
- PERFORM VVEL CONTROL SHAFT POSITION SENSOR ADJUSTMENT
WITHOUT CONSULT
- Disconnect VVEL control shaft position sensor harness connector.
- Remove VVEL actuator motor relay.
- Turn ignition switch ON, wait at least 5 seconds and then turn it OFF.
- Reconnect all harness connectors disconnected.
- Install VVEL actuator motor relay.
- Turn ignition switch ON and wait at least 5 seconds.
- Loosen the VVEL control shaft position sensor mounting bolts (1).
- Turn the VVEL control shaft position sensor (2) clockwise and counterclockwise while monitoring the output voltage between the VVEL control module terminals with a tester and adjust the output voltage to be within the standard value.
VVEL control module Voltage Bank Connector + - Terminal Terminal 1 F56 3 6 500 +- 48 mV 2 5 4 - Tighten the VVEL control shaft position sensor mounting bolts.
:
7.0 N•m (0.71 kg-m, 62 in-lb) - Reconfirm that the output voltage of VVEL control shaft position sensor is within the standard value.
VVEL control module Voltage Bank Connector + - Terminal Terminal 1 F56 3 6 500 +- 48 mV 2 5 4 NOTE:If it varies from the standard value after the mounting bolts are tightened, perform steps 7 to 9 again.
- Turn ignition switch OFF and wait at least 10 seconds.
- Start engine and warm it up to normal operating temperature.
- Turn ignition switch OFF and wait at least 10 seconds.
- Perform Idle Air Volume Learning. Refer to DESCRIPTION .
INSPECTION END