Work Procedure
- PRECONDITION-1
With CONSULT
- Turn ignition switch ON.
- On the CONSULT screen, select "ENGINE">>"WORK SUPPORT">>"RESETTING OF ADAPTION VALUES".
- Touch "Start".
GO TO 2.
- PRECONDITION-2
With CONSULT
Check the following conditions.
ENGINE SPEED
≤ 10 1/min
COOLANT TEMPERATURE
5 deg.C (41 deg.F) ≤ temperature ≥ 100 deg.C (212 deg.F)
ACCEL PEDAL SENSOR
≤ 5%
Is the condition satisfied?
YES
GO TO 3.
NO
Satisfy the condition, and GO TO 3.
- START
With CONSULT
Touch "Start" and wait a few seconds.
Is "COMPLETED" displayed on CONSULT screen?
YES
END
NO
Follow the instruction of CONSULT display.