Detailed Flow
- GET INFORMATION FOR SYMPTOM
Get the detailed information about symptom from customer.
GO TO 2.
- CHECK DTC
- Check DTC of "All DTC Reading" using CONSULT.
- Perform the following procedure if DTC is displayed.
- Record DTC and freeze frame data. (Or, write it down.)
- Check related service bulletins for information.
Is any DTCs detected?
YES
Perform the trouble diagnosis for DTC indicated.
NO
GO TO 3.
- CONFIRM THE SYMPTOM
Try to confirm the symptom described by the customer.
Also study the normal operation related to the symptom. Refer to Handling Precaution
GO TO 4.
- CHECK DRIVE MODE SWITCH CIRCUIT
Check drive mode switch circuit. Refer to Diagnosis Procedure .
Is inspection result normal?
YES
GO TO 5.
NO
Repair or replace error-detected parts.
- CHECK DRIVE MODE SWITCH AND METER INDICATION
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Check that STANDARD is displayed on the information display screen of the combination meter.
- Check that the view of information display changes as STANDARD => SPORT => PERSONAL when switching the drive mode switch to up side.
- Check that the view of information display changes as PERSONAL => SPORT => STANDARD => ECO when switching the drive mode switch to down side.
Is the inspection result normal?
YES
Inspection End.
NO
Check intermittent incident. Intermittent Incident .