Sensor Range Charts: Specifications: Notes
COOLANT TEMP SENSOR SPECIFICATIONS (FUEL INJECTED)
| Temperature: °F (°C) |
Resistance: Ohms |
| 0 (-18) |
25,000 |
| 20 (-7) |
13,500 |
| 40 (4) |
7500 |
| 70 (20) |
3400 |
| 100 (38) |
1800 |
| 160 (70) |
450 |
| 212 (100) |
185 |
MAP SENSOR VOLTAGE (1.5L CARBURETED)
| Vacuum Reading: In. Hg |
Voltage |
| 4.4 |
.12-.38 |
| 11.8 |
1.52-1.69 |
| 27.8 |
4.44-4.60 |
| 30.0 |
4.86-5.04 |
NOTE:
MAP sensor operating range not available for I-Mark 1.5L Turbo.
MAP SENSOR VOLTAGE (1.6L DOHC)
| Altitude: Feet |
Voltage |
| Below 1000 |
3.8-5.5 |
| 1000-2000 |
3.6-5.3 |
| 2000-3000 |
3.5-5.1 |
| 3000-4000 |
3.3-5.0 |
| 4000-5000 |
3.2-4.8 |
| 5000-6000 |
3.0-4.6 |
| 6000-7000 |
2.9-4.5 |
| 7000-8000 |
2.8-4.3 |
| 8000-9000 |
2.6-4.2 |
MAT SENSOR RESISTANCE
| Temperature: °F (°C) |
Resistance: Ohms |
| I-Mark 1.5L Turbo |
| 25 (-4) |
100,707 |
| 32 (0) |
9423 |
| 68 (20) |
3515 |
| 104 (40) |
1459 |
| 140 (60) |
667 |
| 176 (80) |
332 |
| 212 (100) |
176 |
| I-Mark 1.6L DOHC |
| 0 (-18) |
25,000 |
| 20 (-7) |
13,500 |
| 39 (4) |
7500 |
| 70 (20) |
3400 |
| 100 (38) |
1800 |
| 160 (70) |
450 |
| 212 (100) |
185 |
OXYGEN SENSOR VOLTAGE TEST
| Condition |
Volts |
| Lean |
.10 |
| Rich |
.9- |
| Bias |
.45 |
THROTTLE POSITION SENSOR RESISTANCE (1.5L CARBURETED)
| Terminal Wire Colors |
Resistance: Ohms |
| Between Red & Black |
3000-6000 |
THROTTLE POSITION SENSOR CHECK (1.5L, CARBURETED)
| Transmission |
Clearance: In. (mm) |
| Automatic |
0.015 (0.0005) |
| Manual |
0.011 (0.0004) |
| Prescribed Angle |
Approx. Degrees |
| Automatic |
10-18 |
| Manual |
8-16 |