Control Unit - Ground Circuits Test

Using a DVOM, touch negative voltmeter lead to a good ground. Touch positive voltmeter lead to each ground terminal. With vehicle running, voltmeter should indicate less than one volt. If voltmeter reading is greater than one volt, check for open, corrosion or loose connection on ground lead. See ECM GROUND LOCATION table for ECM ground location.

ECM GROUND LOCATION

Application Location
Amigo & Pickup Right Side of Intake Manifold
Impulse Left Side of Upper Intake Manifold
Trooper 2.6L Right Side of Intake Manifold
Trooper 2.8L Right Side, Below Intake Manifold