Code 13 (SOHC) - O2 Sensor (Non-Heated Sensor) Open/Shorted Circuit: Notes

The ECM supplies a .45 volt signal between terminals D6 and D7. When O2 sensor reaches operating temperature, it varies this voltage from approximately .1-.9 volt (lean to rich exhaust). O2 sensor does not produce voltage when temperature is less than 600°F (316°C) or when engine operates in open loop.

NOTE: Test numbers refer to test numbers on diagnostic chart.
  1. Code 13 will set if all the following conditions are met for 255 seconds:
    • Engine temperature is greater than 157°F (69.5°C).
    • Engine has been running for at least 50 seconds after start.
    • O2 signal voltage steady between .35 and .55 volt.
    • Throttle angle greater than 8 percent.

    If conditions for Code 13 exist, system will not go into closed loop.

  2. This determines if sensor, wiring or ECM is the cause of Code 13.
  3. Use only a high impedance (10-megohm) digital volt-ohmmeter. This tests continuity of circuits No. 412 and 413. If circuit No. 413 is open, ECM voltage on circuit No. 412 will be greater than .6 volt.