LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Isuzu >> 1993 >> Stylus Automatic >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Tests W/Codes >> Code Charts >> Code 44 (DOHC) - O2 Sensor Lean Fuel Mixture (Heated Sensor) >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Code 44 (DOHC) - O2 Sensor Lean Fuel Mixture (Heated Sensor): Notes

ECM supplies a voltage of approximately .43 volt between ECM terminals D6 and D7 (if measurement is taken with a 10-megohm DVOM, reading may be as low as .32 volt). The O2 sensor varies voltage from approximately .1 volt (lean exhaust) to 1.0 volt (rich exhaust). When sensor temperature is less than 600°F (316°C), the sensor acts like an open circuit and will not produce voltage. An open sensor circuit or cold sensor will cause an open loop condition.

NOTE: Test numbers refer to test numbers on diagnostic chart.
  1. Code 44 will set under following conditions:
    • Coolant temperature is greater than 158°F (70°C).
    • Engine running for more than 50 seconds.
    • Integrator count is not at 128.
    • No Code 21A, 21B, 33A or 33B is set.
    • O2 sensor voltage is below .280 mV.
    • System is in closed loop.
    • TPS is greater than 10 percent (A/T) or 8 percent (M/T).