NOTE: Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
ENGINE COOLANT TEMPERATURE (ECT) SENSOR RESISTANCE (2.2L HOMBRE)

Temperature °F (°C) Ohms
212 (100) 177
194 (90) 241
158 (70) 467
122 (50) 973
104 (40) 1459
86 (30) 2238
68 (20) 3520
50 (10) 5670
ENGINE COOLANT TEMPERATURE (ECT) SENSOR RESISTANCE (2.2L EXCEPT HOMBRE)

Temperature °F (°C) Ohms
212 (100) 177
176 (80) 332
140 (60) 667
113 (45) 1188
95 (35) 1802
77 (25) 2796
59 (15) 4450
41 (5) 7280
23 (-5) 12300
5 (-15) 21450
-22 (-30) 52700
-40 (-40) 100700
ENGINE COOLANT TEMPERATURE (ECT) & INTAKE AIR TEMPERATURE (IAT) SENSOR RESISTANCE (3.2L & 3.5L)

Temperature °F (°C) Ohms
-40 (-40) 100,700
-22 (-30) 52,700
5 (-15) 21,450
23 (-5) 12,300
41 (5) 7280
59 (15) 4450
77 (25) 2796
95 (35) 1802
113 (45) 1188
140 (60) 667
176 (80) 332
212 (100) 177
FUEL LEVEL SENSOR SPECIFICATIONS (3.2L)

Position Ohms
E 102.5-120.5
1/6 73
1/3 56
1/2 45
2/3 36.75
5/6 30
F 17-23.5
INTAKE AIR TEMPERATURE (IAT) SENSOR RESISTANCE (2.2L HOMBRE)

Temperature °F (°C) Ohms
212 (100) 177
194 (90) 241
158 (70) 467
122 (50) 973
104 (40) 1459
86 (30) 2238
68 (20) 3520
50 (10) 5670
INTAKE AIR TEMPERATURE (IAT) SENSOR RESISTANCE (2.2L EXCEPT HOMBRE)

Temperature Ohms
212°F (100°C) 1177
140°F (60°C) 1667
95°F (35°C)
11802
77°F (25°C) 12796
41°F (5°C) 17280
23°F (-5°C) 121450
5°F (-15°C) 152700
OXYGEN SENSOR VOLTAGE

Condition (1) Volts
Lean 0.1
Rich 1.0
(1) Test at normal operating temperature.