Freeze-Frame Data
Engine operating conditions which cause MIL to illuminate are recorded in PCM memory. This record, called freeze frame data, is a snap shot of the driving conditions that are recorded on the PCM freeze frame buffer and is constantly updated with the most current information.
Freeze frame data can only be overwritten with misfire or fuel trim malfunction data. The data can only be erased by clearing associated history DTCs.