Procedure 1
- Place selector lever in neutral.
- Remove selector lever from the mode switch.
- Remove the mode switch cover.
- Loosen the two 10 mm screws.
- Rotate the mode switch until the slot in the mode switch housing aligns with the selector shaft bushing, and insert a 3/32 in. (2.4 mm) drill bit or punch (1) into the slot.
- Tighten the screws to 13 N.m (113 lb in).
- After completing adjustment, snap the mode switch cover into place.
- Reinstall the selector lever.