Evaporative Systems Test
EVAP test checks EVAP system power operation.
- Connect TECH 2 or equivalent scan tool to Data Link Connector (DLC). DLC is located at lower left side of instrument panel, behind a small cover. Start engine, and go to next step.
- On scan tool select F3: MISCELLANEOUS TESTS. From application menu select F2: EVAP, and go to next step.
- Follow scan tool directions to test EVAP purge control solenoid.
- If EVAP purge control solenoid test as specified, testing is complete. If EVAP purge control solenoid fails test, test EVAP purge control solenoid. For testing procedure, see DTC P0444 Or DTC P0445 .