LEMON Manuals
: Even more car manuals for everyone: 1960-2025
Home
>>
Isuzu
>>
2003
>>
Rodeo 2WD L4-2.2L
>>
Repair and Diagnosis
>>
Powertrain Management
>>
Computers and Control Systems
>>
Description and Operation
>>
Fuel Metering System
>>
Fuel Metering System Modes
>>
Engine Speed/Vehicle Speed/Fuel Disable Mode
April 5, 2026:
LEMON Manuals is launched!
Read the announcement.
Engine Speed/Vehicle Speed/Fuel Disable Mode
The
PCM
monitors engine speed. It turns off the fuel injectors when the engine speed increases above
6000 RPM
. The fuel injectors are turned back on when engine speed decreases below
5750 RPM
.