Function Check
Use a Tech 2 to check the TP sensor output voltage at closed throttle.
- The voltage should be TP1 about 0.4V, TP2 about 4.6V and TPS about 4.6V.
- If the reading is abnormal value, check the throttle shaft to see if it is binding.
Use a Tech 2 to check the TP sensor output voltage at closed throttle.