Inspection and Repair

Insert special tool in end of torque converter.

Insert a turning tool into the inner race of the one-way clutch.

One-way clutch testing tool:  J-35467

Insert the stopper so that it fits in the notch of the converter hub and outer race of the one-way clutch.

Fig 1: Inserting Special Tool In End Of Torque Converter
G02789516Courtesy of ISUZU MOTOR CO.
  1. One-way clutch test.

The clutch should lock when turned counterclockwise, and rotate freely and smoothly clockwise. Less than 2.5 N°Cm (22 lb in) of torque should be required to rotate the clutch clockwise. If necessary, clean the converter and retest the clutch. Replace the converter if the clutch still fails the test.