Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the automatic transmission shift lock actuator.
- Ignition OFF, test for less than 1.0 ohm between the ground circuit terminal A and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition ON, verify that a test lamp illuminates between the control circuit terminal B and ground.
- If the test lamp does not illuminate, test the park lock solenoid and A/T shift lock control solenoid control circuits for an open or short to ground. If all circuits test normal, test or replace the automatic transmission shift lock actuator.
- Ignition ON, verify that a test lamp illuminates between the control circuit terminal E and ground.
- If the test lamp does not illuminate, test the A/T shift lock control solenoid control circuit for an open. If all circuits test normal, test or replace the stop lamp switch.
- Ignition ON, verify that a test lamp does not illuminate between the control circuit terminal E and ground when the brake pedal is depressed.
- If the test lamp illuminates, test the A/T shift lock control solenoid control circuit for a short to voltage. If all circuits test normal, test or replace the stop lamp switch.
- If all circuits test normal, test or replace the automatic transmission shift lock actuator.