Solenoid Valve
With ignition switch OFF, remove vacuum pipes from valve and connect suitable length of hose to thermostatic switch port. Blow into hose, air should emit from throttle edge tapping port. Switch ON ignition, and again blow through hose. Air should be emitted from adjacent port. If valve fails to operate as described, either valve or electrical feed is defective.