Air Injection System: Testing: XJ6
- Warm engine to operating temperature and allow to idle. Disconnect air by-pass hose at air cleaner. Air should be coming out with engine warm. If not, check air pump and switching valve wiring.
- Disconnect electrical wiring at thermal switch and connect leads together. Air should stop at by-pass hose. If not, check wiring and switching valve operation.
- Connect CO meter to both exhaust manifold check ports. With no air injection and engine warm, CO level should be 0.1-0.3%. Disconnect thermal switch leads and connect them together. Mixture should stabilize at 0.1-0.3%. If not, check vacuum to switching valve.
- Disconnect air switching module connector. CO level should rise to 0.4-0.6%. Reconnect thermal switch and air switching module; CO level should return to normal. If system does not operate as described, replace switching module.