Sensor Operating Range Charts

NOTE: Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
COOLANT TEMPERATURE SENSOR RESISTANCE (1)

Temperature °F (°C) Ohms
32 (0) 5000-8000
50 (10) 3000-5000
68 (20) 2000-3000
86 (30) 1500-2000
104 (40) 1000-1500
122 (50) 700-1000
140 (60) 600-800
158 (70) 300-600
176 (80) 260-400
(1) Resistance values are approximate. Check sensor in heated water.
EGR TEMPERATURE SENSOR RESISTANCE (1)

Temperature °F (°C) Ohms
212 (100) 60,000-100,000
302 (150) 15,000-25,000
392 (200) 3000-8000
482 (250) 1500-2500
572 (300) 400-1000
662 (350) 250-350
(1) Resistance values are approximate. Check sensor in boiling water.
HEATED OXYGEN SENSOR VOLTAGE

Condition Volts
Lean .1
Rich .9
INTAKE AIR TEMPERATURE SENSOR RESISTANCE (1)

Temperature °F (°C) Ohms
32 (0) 5000-8000
50 (10) 3000-5000
68 (20) 2000-3000
86 (30) 1500-2000
104 (40) 1000-1500
122 (50) 700-1000
140 (60) 600-800
158 (70) 300-600
176 (80) 260-400
(1) Resistance values are approximate.
MASS AIRFLOW SENSOR VOLTAGE (1)

Condition Volts
Idle .10-1.40
Full Throttle 3.0-3.3
(1) Measure voltage between terminals No. 1 and 3.