VER-1: Verification Procedure VER-1
Inspect vehicle to ensure that all components are connected. Reassemble and reconnect components as necessary. Attempt to start engine. If engine does not start, perform NO START TEST NS-1A: CHECKING FOR FAULT MESSAGES & SPARK .
If engine starts and the engine controller has been replaced, perform the following steps.
- If vehicle is equipped with a factory theft alarm system, start vehicle at least 20 TIMES so that the theft alarm system may be activated when desired.
- Write (transfer) EMR mileage into new engine controller. See EMISSION MAINTENANCE REMINDER (EMR) MILEAGE TRANSFER .
- The no start condition has been corrected. The repair procedure is now complete. If engine starts and the engine controller has NOT been replaced, perform the following steps:
- Connect DRB-II to engine diagnostic connector and erase faults.
- The no start condition has been corrected and the fault messages have been erased. The repair procedure is now complete.