Blank DRB-II Message Screen
- Connect DRB-II to a different vehicle. If message screen is still blank, DRB-II or cable adapter are faulty. Substitute to find faulty component.
- If message screen is not blank, DRB-II and cable adapter are functioning properly. Inspect diagnostic connector for proper wire placement, damaged terminals or pushed out pins. Repair as necessary.
- If diagnostic connector is okay, use a DVOM to check resistance between ground and Black wire (Black/Yellow wire on Wrangler) at engine diagnostic connector. If resistance is 10 ohms or more, repair open in Black wire (Black/Yellow wire on Wrangler).