Test 7E - Short To Battery
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION in this article. For appropriate wiring diagram, see WIRING DIAGRAMS section at the end of this article.
- Using scan tool in ohmmeter mode, check instrument cluster connector ground circuit (Black/Light Green wire).
- If resistance is more than 5 ohms, repair open Black/Light Green wire. Perform TEST VER-1 . If resistance is less than 5 ohms, replace instrument cluster. Perform TEST VER-1 .