Cluster Wake Up Output Low
Monitored & Set Condition
- When Monitored: With the ignition in the Off position.
- Set Condition: When the BCM receives an input from the driver door switch or an input from exterior lamp control switch. Symptoms will include: No fast chime with key in ignition or Park Lamps on and driver door open. No VF odometer display when door open. No cluster, high beam indicator, front or rear lamp indicator illumination.
Possible Causes:
- Fused B+ Circuit Open
- Instrument Cluster Wake Up Signal Circuit Open
- Intermittent Condition
- Instrument Cluster Wake Up Signal Circuit Short To Ground
- Body Control Module
- Instrument Cluster
Testing
- Turn the ignition off. Disconnect the Instrument Cluster harness connector. Measure the voltage between the Fused B+ circuit and ground. Is the voltage above 10.5 volts? If yes, go to next step. If no, repair the Fused B+ circuit for an open. Perform BODY VERIFICATION TEST .
- Turn the ignition off. Disconnect the Instrument Cluster harness connector. Disconnect the BCM C1 harness connector. Measure the resistance of the Instrument Cluster Wake Up Signal circuit. Is the resistance above 5.0 ohms? If yes, repair the Instrument Cluster Wake Up Signal circuit for an open. Perform BODY VERIFICATION TEST . If no, go to next step.
- Turn the ignition off. Disconnect the Instrument Cluster harness connector. Disconnect the BCM C1 harness connector. Measure the resistance between ground and the Cluster Wake Up circuit. Is the resistance below 5.0 ohms? If yes, repair the Instrument Cluster Wake Up Signal circuit for a short to ground. Perform BODY VERIFICATION TEST . If no, go to next step.
- Turn the ignition off. Disconnect the Instrument Cluster harness connector. Ensure that the BCM C1 harness connector is connected. Install a DVOM between the Cluster Wake Up circuit of the Instrument Cluster harness connector and ground. Set the DVOM to read resistance. Turn the ignition on. With the DRBIII(R), select Body Control Module, then Actuators. Observe the DVOM while using the DRBIII(R) to actuate the Cluster Wake Up "on." Did the DVOM indicate a brief (2 second) continuity to ground? If yes, go to next step. If no, replace the Body Control Module. See BODY CONTROL MODULE (BCM) in REMOVAL & INSTALLATION. Perform BODY VERIFICATION TEST .
- Turn the ignition off. Ensure that the Instrument Cluster and BCM C1 harness connectors are connected. Open the driver door or actuate the High Beam Headlamps with the key off. With the DRBIII(R), read DTCs. Did this DTC reset? If yes, replace the Instrument Cluster in accordance with the Service Information. Perform BODY VERIFICATION TEST . If no, the condition is not present at this time. Monitor DRBIII(R) DTCs while wiggling the related wire harness. Refer to any Technical Service Bulletins (TSB) that may apply. Visually inspect the related wiring harness and connector terminals.