Similar Conditions Window: Misfire
- Same Misfire Warm-Up State
Indicates if the misfire occurred when the engine was warmed up (above 160° F).
- In Similar Misfire Window
An indicator that "Absolute MAP When Misfire Occurred" and "RPM When Misfire Occurred" are all in the same range when the failure occurred. Indicated by switching from "NO" to "YES".
- Absolute MAP When Misfire Occurred
The stored MAP reading at the time of failure. Informs the user at what engine load the failure occurred.
- Absolute MAP
A live reading of engine load to aid the user in accessing the Similar Conditions Window.
- RPM When Misfire Occurred
The stored RPM reading at the time of failure. Informs the user at what engine RPM the failure occurred.
- Engine RPM
A live reading of engine RPM to aid the user in accessing the Similar Conditions Window.
- Adaptive Memory Factor
The PCM utilizes both Short Term Compensation and Long Term Adaptive to calculate the Adaptive Memory Factor for total fuel correction.
- 200 Rev Counter
Counts 0-100 720 degree cycles.
- SCW Cat 200 Rev Counter
Counts when in similar conditions.
- SCW FTP 1000 Rev Counter
Counts 0-4 when in similar conditions.
- Misfire Good Trip Counter
Counts up to three to turn OFF the MIL.
- Misfire Data
Data collected during test.
- Test Done This Trip
Indicates YES when the test is done.