Possible Causes
| Possible Causes |
|---|
| INTERMITTENT DTC |
| (K857) 5 VOLT SUPPLY CIRCUIT SHORTED TO VOLTAGE |
| (K44) CMP 1/1 SIGNAL CIRCUIT SHORTED TO VOLTAGE |
| (K857) 5 VOLT SUPPLY CIRCUIT SHORTED TO GROUND |
| (K44) CMP 1/1 SIGNAL CIRCUIT SHORTED TO GROUND |
| (K857) 5 VOLT SUPPLY CIRCUIT SHORTED TO THE (K44) CMP 1/1 SIGNAL CIRCUIT |
| (K857) 5 VOLT SUPPLY CIRCUIT SHORTED TO THE (K900) SENSOR GROUND CIRCUIT |
| (K44) CMP 1/1 SIGNAL CIRCUIT SHORTED TO THE (K900) SENSOR GROUND CIRCUIT |
| (K857) 5 VOLT SUPPLY CIRCUIT OPEN OR HIGH RESISTANCE |
| (K44) CMP 1/1 SIGNAL CIRCUIT OPEN OR HIGH RESISTANCE |
| (K900) SENSOR GROUND CIRCUIT OPEN OR HIGH RESISTANCE |
| CAMSHAFT 1/1 POSITION SENSOR |
| CAMSHAFT 1/2 POSITION SENSOR |
| POWERTRAIN CONTROL MODULE (PCM) |
Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. Refer to PRE-DIAGNOSTIC TROUBLESHOOTING PROCEDURE .