LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Jeep >> 2014 >> Cherokee Sport, AWD >> Repair and Diagnosis >> Quick Lookups >> DTC Index >> HVAC, ATC - LHD
April 5, 2026: LEMON Manuals is launched! Read the announcement.

HVAC, ATC - LHD

DIAGNOSTIC CODE INDEX

DTC Description
B1000-92 A/C SWITCH REQUEST INPUT - PERFORMANCE OR INCORRECT OPERATION
B1009-92 RECIRCULATION SWITCH REQUEST INPUT - PERFORMANCE OR INCORRECT OPERATION
B1015-92 EBL REAR DEFROST SWITCH REQUEST INPUT - PERFORMANCE OR INCORRECT OPERATION
B1030-11 EVAPORATOR TEMPERATURE SENSOR - CIRCUIT SHORT TO GROUND
B1030-15 EVAPORATOR TEMPERATURE SENSOR - CIRCUIT SHORT TO BATTERY OR OPEN
B1058-11 RECIRCULATION DOOR CONTROL - CIRCUIT SHORT TO GROUND
B1058-12 RECIRCULATION DOOR CONTROL-CIRCUIT SHORT TO BATTERY
B1058-13 RECIRCULATION DOOR CONTROL-CIRCUIT OPEN
B1058-92 RECIRCULATION DOOR CONTROL - PERFORMANCE OR INCORRECT OPERATION
B105C-00 RECIRCULATION DOOR-TRAVEL RANGE TOO SMALL
B105D-00 RECIRCULATION DOOR TRAVEL - RANGE TOO LARGE
B10B2-00 A/C COOL - DOWN TEST PERFORMANCE
B10B3-11 CABIN HEATER 1 CONTROL - CIRCUIT SHORT TO GROUND
B10B3-13 CABIN HEATER 1 CONTROL - CIRCUIT OPEN
B10B7-11 CABIN HEATER 2 CONTROL - CIRCUIT SHORT TO GROUND
B10B7-13 CABIN HEATER 2 CONTROL - CIRCUIT OPEN
B10E8-11 BLOWER MOTOR CONTROL - CIRCUIT SHORT TO GROUND
B10E8-12 BLOWER MOTOR CONTROL - CIRCUIT SHORT TO BATTERY
B10E8-16 BLOWER MOTOR CONTROL - CIRCUIT VOLTAGE BELOW THRESHOLD
B10E8-17 BLOWER MOTOR CONTROL - CIRCUIT VOLTAGE ABOVE THRESHOLD
B1107-11 CABIN TEMPERATURE SENSOR 1 - CIRCUIT SHORT TO GROUND
B1107-15 CABIN TEMPERATURE SENSOR 1 - CIRCUIT SHORT TO BATTERY OR OPEN
B1137-11 CABIN HEATER 3 CONTROL - CIRCUIT SHORT TO GROUND
B1137-13 CABIN HEATER 3 CONTROL - CIRCUIT OPEN
B11C2-11 FRONT MODE DOOR 1 CONTROL - CIRCUIT SHORTED TO GROUND
B11C2-12 FRONT MODE DOOR 1 CONTROL - CIRCUIT SHORT TO BATTERY
B11C2-13 FRONT MODE DOOR 1 CONTROL - CIRCUIT OPEN
B11C2-92 FRONT MODE DOOR 1 CONTROL-PERFORMANCE OR INCORECT OPERATION
B11C3-00 FRONT MODE DOOR 1 TRAVEL - RANGE TOO SMALL
B11C4-00 FRONT MODE DOOR 1 TRAVEL - RANGE TOO LARGE
B11C8-11 RIGHT TEMPERATURE DOOR CONTROL - CIRCUIT SHORT TO GROUND
B11C8-12 RIGHT TEMPERATURE DOOR CONTROL-CIRCUIT SHORT TO BATTERY
B11C8-13 RIGHT TEMPERATURE DOOR CONTROL - CIRCUIT OPEN
B11C8-92 RIGHT TEMPERATURE DOOR CONTROL - PERFORMANCE OR INCORECT OPERATION
B11C9-00 RIGHT TEMPERATURE DOOR - TRAVEL TOO SMALL
B11CA-00 RIGHT TEMPERATURE DOOR - TRAVEL TOO LARGE
B11CB-11 MAIN/LEFT TEMPERATURE DOOR CONTROL - CIRCUIT SHORT TO GROUND
B11CB-12 MAIN/LEFT TEMPERATURE DOOR 1 CONTROL - CIRCUIT SHORT TO BATTERY
B11CB-13 MAIN/LEFT TEMPERATURE DOOR 1 CONTROL - CIRCUIT OPEN
B11CB-92 MAIN/LEFT TEMPERATURE DOOR 1 CONTROL - PERFORMANCE OR INCORRECT OPERATION
B11CC-00 MAIN/LEFT TEMPERATURE DOOR 1 - TRAVEL TOO SMALL
B11CD-00 MAIN/LEFT TEMPERATURE DOOR 1 - TRAVEL TOO LARGE
B11D3-00 A/C COOL DOWN TEST PERFORMANCE - COMPRESSOR CLUTCH NOT ENGAGED
B11D5-00 A/C COOL DOWN TEST PERFORMANCE - EVAP TEMP SENSOR ERROR
B11D9-92 BLOWER SPEED KNOB REQUEST INPUT - PERFORMANCE OR INCORRECT OPERATION
B11DB-92 MODE SWITCH REQUEST INPUT - PERFORMANCE OR INCORRECT OPERATION
B11E9-92 LEFT TEMPERATURE KNOB REQUEST INPUT-PERFORMANCE OR INCORRECT OPERATION
B11F0-11 LEFT FLOOR DUCT TEMPERATURE SENSOR-CIRCUIT SHORT TO GROUND
B11F0-15 LEFT FLOOR DUCT TEMPERATURE SENSOR - CIRCUIT SHORT TO BATTERY OR OPEN
B11F1-11 RIGHT FLOOR DUCT TEMPERATURE SENSOR-CIRCUIT SHORT TO GROUND
B11F1-15 RIGHT FLOOR DUCT TEMPERATURE SENSOR - CIRCUIT SHORT TO BATTERY OR OPEN
B11F2-11 LEFT PANEL DUCT TEMPERATURE SENSOR - CIRCUIT SHORT TO GROUND
B11F2-15 LEFT PANEL DUCT TEMPERATURE SENSOR - CIRCUIT SHORT TO BATTERY OR OPEN
B11F3-11 RIGHT PANEL DUCT TEMPERATURE SENSOR-CIRCUIT SHORT TO GROUND
B11F3-15 RIGHT PANEL DUCT TEMPERATURE SENSOR - CIRCUIT SHORT TO BATTERY OR OPEN
B11F4-11 MODE/TEMPERATURE DOOR FEEDBACK VOLTAGE REFERENCE - CIRCUIT SHORT TO GROUND
B11F4-12 MODE/TEMPERATURE DOOR FEEDBACK VOLTAGE REFERENCE - CIRCUIT SHORT TO BATTERY
B11FE-11 VARIABLE A/C COMPRESSOR CONTROL - CIRCUIT SHORT TO GROUND
B11FE-12 VARIABLE A/C COMPRESSOR CONTROL - CIRCUIT SHORT TO BATTERY
B11FE-13 VARIABLE A/C COMPRESSOR CONTROL - CIRCUIT OPEN
B1600-11 LEFT SOLAR SENSOR-CIRCUIT SHORT TO GROUND
B1600-12 LEFT SOLAR SENSOR - CIRCUIT SHORT TO BATTERY
B1603-11 RIGHT SOLAR SENSOR - CIRCUIT SHORT TO GROUND
B1603-12 RIGHT SOLAR SENSOR - CIRCUIT SHORT TO BATTERY
B160F-11 TWILIGHT/AMBIENT LIGHT SENSOR INPUT - CIRCUIT SHORT TO GROUND
B160F-12 TWILIGHT/AMBIENT LIGHT SENSOR INPUT-CIRCUIT SHORT TO BATTERY
B210D-84 BATTERY VOLTAGE LOW - SIGNAL BELOW ALLOWABLE RANGE
B210E-85 BATTERY VOLTAGE HIGH - SIGNAL ABOVE ALLOWABLE RANGE
B2214-00 HVAC CLIMATE CONTROL - INTERNAL ERROR
B222A-00 VEHICLE LINE MISMATCH
U0010-00 CAN INTERIOR BUS
U0011-00 CAN INTERIOR BUS OFF PERFORMANCE
U0140-00 LOST COMMUNICATION WITH BODY CONTROL MODULE
U0155-00 LOST COMMUNICATION WITH CLUSTER/CCN
U0184-00 LOST COMMUNICATION WITH RADIO
U0401-00 IMPLAUSIBLE DATA RECEIVED FROM ECM/PCM
U0422-00 IMPLAUSIBLE DATA RECEIVED FROM BODY CONTROL MODULE
U0423-00 IMPLAUSIBLE DATA RECEIVED FROM THE CLUSTER/CCN
U11B8-00 LOST COMMUNICATION WITH THE INTEGRATED CENTER STACK ICS