  1. Install the variable valve timing solenoid seals (1). The seals can be reused if not damaged.
    GC0144211Courtesy of CHRYSLER GROUP, LLC
  2. Refer to the markings made at disassembly and install the intake variable valve timing solenoid (2) and the exhaust variable valve timing solenoid (4) in their original locations.
  3. Install the variable valve timing solenoid mounting bolts (3) and tighten to 4 N.m (35 in. lbs.).
  4. Connect the electrical connector (1) to the variable valve timing solenoid.
    GC0154034Courtesy of CHRYSLER GROUP, LLC
  5. Secure the heater core tube assembly to the right upper intake manifold support bracket with two nuts (3) tightened to 12 N.m (106 in. lbs.).
  6. Install the engine cover. Refer to COVER, ENGINE, INSTALLATION .
  7. Connect the negative battery cable.
NOTE:

The Cam/Crank Variation Relearn procedure must be performed using the scan tool anytime there has been a repair/replacement made to a powertrain system, for example: flywheel, valvetrain, camshaft and/or crankshaft sensors or components.