Sensor, Air Temperature, Intake: Removal: 6.4L
The Intake Air Temperature (IAT) sensor (4) is installed into the air cleaner duct (3).
- Disconnect the electrical connector at the IAT sensor (4).
- Gently lift on the small plastic release tab and rotate the IAT sensor about 1/4 turn counter-clockwise and remove.
- Check condition of sensor O-ring, replace if necessary.