Generator Inspection
- Inspect the battery condition.
- Inspect condition of battery cable and terminals, battery posts, connections at engine block, starter solenoid and relay.
- Inspect all fuses in both the engine compartment fuse/relay box and the passenger compartment fuse box.
- Inspect the generator mounting bolts for tightness.
- Inspect the generator drive belt condition and tension.
- Inspect connections at generator field, battery output and ground terminals. Check ground connection at engine.