Charging Systems: General: Generator: Installation
- Position generator on engine.
- Install pivot bolt (leave loose).
- Rotate bracket into position on top of generator.
- Place belt tensioner into position on adjustment bracket.
- Install tensioner mounting bolt (leave loose).
- Place drive belt on generator pulley.
- Adjust belt tension by rotating adjustment bolt.
- Allowable deflection:
- New belt: 0.23 - 0.31 in (6 - 8 mm)
- Old belt: 0.28 - 0.35 in ( 7 - 9 mm)
- Allowable deflection:
- Tighten tensioner bolt.
Tighten tensioner bolt to: 14~19 lb-ft (19~26 N.m)
- Tighten pivot bolt and bracket bolt.
Tighten pivot and bracket bolt to: 28~38 lb-ft (38~51 N.m)
- Connect generator L and S terminal connectors.
- Connect B terminal lead.
- Install and tighten B terminal nut.
- Close B terminal nut cover.
- Install air intake inlet pipe and tighten end clamp.
- Connect top hose to air intake inlet pipe.
- Install front air intake inlet pipe bolts.
- Connect negative battery cable.CAUTION:
- Be sure battery connections are not reversed. This will damage rectifier.
- Do not use high voltage testers, such as a megger. They will damage the rectifier.
- Remember that battery voltage is always applied to alternator B terminal.
- Do not ground L terminal while engine is running.
- Do not start engine while L and S terminals are disconnected from generator.