LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Kia >> 2007 >> Spectra5 2.0 1, Automatic >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Gasoline Engine Control System >> Heated Oxygen Sensor (Ho2S) >> Inspection >> Function And Operation Principle
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Function And Operation Principle

Heated Oxygen Sensor (HO2S) consists of zirconium and alumina and is installed on upstream and downstream of the Manifold Catalyst Converter (MCC). After it compares oxygen consistency of the atmosphere with the exhaust gas, it transfers the oxygen consistency of the exhaust gas to the ECM. In order that this sensor normally operates, the temperature of the sensor tip is higher than 370 °C (698°F). So it has a heater which is controlled by the ECM duty signal. When the exhaust gas temperature is lower than the specified value, the heater warms the sensor tip.