Charging System Test Results
CHARGING SYSTEM TEST RESULTS
| RESULT ON PRINTER | REMEDY |
|---|---|
| Charging system normal/Diode ripple normal | Charging system is normal |
| No charging voltage | Generator does not supply charging current to battery |
| => Check belts, connection between generator and battery | |
| Replace belts or cable or generator as necessary | |
| Low charging voltage | Generator does not supply charging current to battery and electrical load to system fully |
| => Check belts and generator and replace as necessary | |
| High charging voltage | The voltage from generator to battery is higher than normal limit during voltage regulating. |
| => Check connection and ground and replace regulator as necessary | |
| => Check electrolyte level in the battery | |
| Excess ripple detected | One or more diodes in the generator is not functioning properly |
| => Check generator mounting and belts and replace as necessary |