| Charging system normal/Diode ripple normal |
Charging system is normal |
| No charging voltage |
Generator does not supply charging current to battery |
| => Check belts, connection between generator and battery |
| Replace belts or cable or generator as necessary |
| Low charging voltage |
Generator does not supply charging current to battery and electrical load to system fully |
| => Check belts and generator and replace as necessary |
| High charging voltage |
The voltage from generator to battery is higher than normal limit during voltage regulating. |
| => Check connection and ground and replace regulator as necessary |
| => Check electrolyte level in the battery |
| Excess ripple detected |
One or more diodes in the generator is not functioning properly |
| => Check generator mounting and belts and replace as necessary |